High Frequency Power Supply for ESP

High Frequency High Voltage Pulse Power Supply for Electrostatic Precipitator


Air-cooled Controller + High voltage generator (LCD Version)

 


Working Principles

NY710144 series High Frequency High Voltage Pulse Power Supply for Electrostatic Precipitator consists of two parts: control cabinet and high voltage generator.

 Circuit principle: 50Hz 3 phase 380VAC input, full bridge controllable rectifier, IGBT inverter to generate high frequency power supply, then through the high frequency transformer to step up the voltage, and finally rectified into high frequency high voltage DC pulse power output.




Application

High Frequency High Voltage Pulse Power Supply for Electrostatic Precipitator is an important part of the electrostatic precipitator system equipment. According to the different requirements of working conditions, it can be widely used in industrial sectors of dust removal, fog removal, desulfurization, dehydration, impurities separation and recycle of rare metals and other occasions, which is an important equipment to protect the environment, comprehensive utilization of resources. Its specific application scope is as follows:

Metallurgical industry: used for black and non-ferrous metal smelting dust removal, recycle of metal smelting raw materials and comprehensive utilization.

Building materials industry: used for dust removal and raw materials recovery in cement and refractory industries.

Electric power industry: used for boiler flue gas dust removal.

Petroleum industry: used to separate salt, water or other impurities contained in crude oil.

Chemical industry: used to recycle valuable components in flue gas, used in acid industry for fog removal, dust removal, etc.

Light textile industry: used for alkali recycle and dust removal in papermaking and textile industry.

Electronics, medicine, machinery industry: for purifying air and improving product quality.

 

Product Models

3 Phase AC Input Voltage

Output Impulse  Frequency

 Output No-load Voltage

 Rated Output Current

Output No-load Voltage

 Rated Output Current

380V

>40kHz

40KV

300mA

80KV

300mA

380V

>40kHz

40KV

600mA

80KV

600mA

380V

>40kHz

40KV

1000mA

80KV

1000mA

380V

>40kHz

40KV

1500mA

80KV

1500mA

380V

>40kHz

40KV

2000mA

80KV

2000mA

380V

>40kHz

60KV

300mA

100KV

300mA

380V

>40kHz

60KV

600mA

100KV

600mA

380V

>40kHz

60KV

1000mA

100KV

1000mA

380V

>40kHz

60KV

1500mA

100KV

1500mA

380V

>40kHz

60KV

2000mA

100KV

2000mA

 

 

 

Technical Parameter

Item

Description

 

 

 

Power supply

input parameter

Input voltage

Three phase 380VAC/50Hz (sine)

Input current

0A~100A

Input voltage error

≤rating value ±10%

Three phase supply voltage unbalance

≤5%

Input overvoltage protection

≥420V

Input undervoltage protection

≤350V

 

 

 

 

 

Power supply

output parameter

 

Output constant mode

constant current

Power supply output voltage standard

40kV, 60kV, 80kV, 100kV (0~max adjustable) 

Power supply output standard current

300mA,600mA, 1000mA,1500mA, 20000mA,(0~max adjustable) 

Output ripple

<1%

Output impulse peak current

>500A

Output frequency

>40KHz

Output DC impulse duty ratio

0~90%;(0~25us

Output short circuit protection

Internal temperature alarm threshold value: 65℃

Cooling method: forced air cooling+forced water cooling

 

 

 

 

 

 

 

 

Environment requirement

Working at an altitude of not more than 2000 meter

Working ambient temperature 

0℃50℃

Storage temperature 

0℃70℃

25℃ Relative air humidity 20%~85%; No condensation or icing

The air shall not contain corrosive steam, particles, conductive particles and particles that will become conductive after absorbing moisture

air cooled

natural air

Water cooling

Cooling water: inlet water temperature ≤30°C, water pressure 1.5–4.0Kg/mm2. Shall adopt the water pipe which can match with a water pipe joint in the size of 8mm (inner diameter) ×12mm (outer diameter). Do not reduce the inner diameter of the cooling water pipe at will.

 

 

Safety Protection

▶  The equipment has the function of heavy and light load protection. When the equipment is under heavy or light load, the secondary current and secondary voltage of the equipment shall be limited below the rated value;

 

▶  Self - check and self - recovery function;

 

▶  One time over current protection function;

 

▶  Short circuit protection function;

 

▶  IGBTIPMfault protection function;

 

▶  Open circuit protection function;

 

▶  Impact resistance function;

 

▶  Transformer oil temperature over limit protection function;

 

▶  IGBTIPMover temperature protection function.

 

Functional Performance

▶  Stability

▶  Reliability

▶  Safety

▶  Environmental adaption

▶  Testability

▶  Maintainability

 

 